Industrial

Slitting line supplier factory 2024

High quality electrical equipment supplier: Harmonics, a crucial aspect of power quality, have a significant long-term impact on distribution transformers. Harmonics refer to the distortion of the normal electric current waveform, usually due to the operation of non-linear loads like computers, LED lights, and variable speed drives. These distortions can cause increased heating in the transformer, leading to accelerated aging and reduced equipment lifespan. Furthermore, harmonics can also increase power demand and system losses. They can overload the transformer and other components of the electrical system, leading to premature failures and necessitating costly repairs or replacements. Thus, managing harmonics is an essential part of maintaining high power quality and ensuring the efficient operation of power distribution transformers. Read even more details on cut to length line.

Why should the iron core of the transformer be grounded? Transformer core grounding is for safety and electromagnetic compatibility considerations. On the one hand, grounding the transformer core prevents contact voltages caused by ground faults, which can pose a shock hazard to humans. Because when a ground fault occurs on one side of the transformer, the iron core on the other side may have a voltage in contact with the earth. If it is not grounded, this voltage cannot be released. On the other hand, grounding the transformer core can also reduce electromagnetic radiation interference, especially for radio equipment and communication systems. This is because the current will generate a magnetic field in the iron core. If the iron core is not grounded, this magnetic field may leak into the surrounding environment and interfere with the normal operation of other equipment. In conclusion, grounding the transformer core is a protective measure against shock hazards and electromagnetic interference.

What is the capacity of the transformer related to? The capacity of the transformer refers to the maximum load electric power that the transformer can bear. The capacity of the transformer is related to the following factors: Input voltage and output voltage: The input voltage and output voltage of the transformer determine the transformation ratio of the transformer, which affects the capacity of the transformer. The higher the input voltage of the transformer and the lower the output voltage, the larger the transformation ratio and the larger the capacity. Load nature: Different loads have different power factors, harmonic content and other characteristics, which affect the capacity of the transformer. For inductive loads, the capacity of the transformer can be appropriately reduced; for nonlinear loads, the capacity of the transformer needs to be appropriately increased.

The trademark “CANWIN” has won the title of the famous trademark of the international electrotechnical association and the trademark CANWIN CNC” has been recognized as a high -end manufacturing brand in China. We has been judged as Guangdong province enterprise that strictly contracts and keeps promises” and won the honor of”excellent supplier of Chinese electrical equipment” successively. The company has a number of national patents, and won the Guangdong provincial department of science and technology major project award the first set of domestic new products award; The company is a key enterprise in the field of electric power electrical equipment manufacturing in China, and a core professional equipment supplier of state grid, China southern power grid and many listed companies in the electric power industry. Its products are exported to countries and regions in Asia, Africa, Latin America, Europe and the United States.

A China slitting line produces longitudinal cuts in a master coil of steel to predetermined narrower widths. These smaller coils are then sent to downstream operations such as metal stampers, tube producers or roll forming houses that will use the material in their final product. Customized slitting line machine equipment mainly includes the following: Loading trolley, double support uncoiler, feeding device, traction leveling machine, trimming shearing machine, deviation correction feeding device, longitudinal shear line, waste edge winder, feed rack, pre separation device, tensioner, feeding roller, winding shearing machine, steering drum, rear axle, discharge trolley, winding auxiliary support, hydraulic system and electrical system, etc.

The cooling methods are divided into natural air cooling (AN) and forced air cooling (AF). When air cooled naturally, the transformer can run continuously for a long time under rated capacity. When forced air cooling, transformer output capacity can be increased by 50%. Suitable for intermittent overload operation, or emergency overload operation; Because the load loss and impedance voltage increase greatly during overload, it is in non-economic operation state, so it should not be in continuous overload operation for a long time.Welcome to inquiry price for dry type substation transformer.

A transformer coil winding machine is an intricate piece of machinery with an essential role in the manufacturing of transformers, combining modern technology and meticulousness to create high-quality products efficiently. The process starts with the feeding of copper wire into the machine, which passes through a line-up of calibrations guides and tensioners designed to secure alignment and prevent damage. An automated system then causes rotation, gradually looping copper wire around the transformer coil. A computerized system oversees variables such as speed, pitch control, layer count and insulation thickness for consistent turns. Moreover, for distinct transformer models or designs, these machines can be fitted with extra features such as automatic lead cutting and tapping mechanisms for increased versatility and productivity.

The transformer core provides a magnetic path to channel flux. The use of highly permeable material (which describes the material’s ability to carry flux), as well as better core construction techniques, helps provide a desirable, low reluctance flux path and confine lines of flux to the core. An electrical distribution cabinet is a part of an electrical system whose task is to distribute electrical energy. It includes distribution, protection, measurement, control and signaling instruments. The electrical distribution box also contains wires, various types of insulation, and support components. Read more info on https://www.canwindg.com/

Laser welding machine is an efficient and precise welding method using high energy density laser beam as a heat source. Laser welding is one of the important applications of laser material processing technology. It mainly used for welding thin wall material and low speed in the 1970 s. The welding process is thermal conduction, i.e. the laser radiation heating surface, the surface heat to the internal diffusion through heat conduction, by controlling the width of laser pulse, energy, peak power and repeating frequency, parameters such as melting of components, to form specific molten pool. Because of its unique advantages, it has been successfully used in precision welding of micro and small parts.As one of the best laser welding machine manufacturers in China, Canwin specialized in handheld laser welding machine and wholesale fiber laser welding machine making for over 20 years.

With the development of the times, people’s demand for power supply and the reliability of power supply are increasingly high, so the smart grid has emerged accordingly.In the power system, the core and hub of the substation is the transformer.The function of the transformer is mainly to distribute and convert electric energy. The normal operation of the transformer directly affects the normal function of the substation.The intelligent operation of the transformer mainly involves the protection and status monitoring of the transformer, so as to achieve real-time monitoring of the transformer and ultimately ensure the safety and reliability of power supply.

Connection group label: According to the phase relationship between the primary and secondary windings of the transformer, the transformer windings are connected into various combinations, which are called the connection group of the windings. In order to distinguish different connection groups, the clock notation is often used, that is, the phasor of the line voltage on the high-voltage side is used as the long hand of the clock, fixed at 12, and the phasor of the line voltage on the low-voltage side is used as the short hand of the clock. The number of the short hand indicates the connection group label. For example, Dyn11 indicates that the primary winding is (triangle) connected, and the secondary winding is (star) connected with a center point, and the group number is (11) points.